Sysmex Europe
Menu

XN-9100 Maximum Workload

The XN-9100 Maximum Workload best serves laboratories with a very high workload of EDTA blood sample tubes. You observe significant order entry peaks and need short turnaround times (TAT), while most of your samples are negative.

Ideally, you could do with two different processing lines: one for screening the bulk of the samples as fast as possible and another for analysing those with conspicuous results further.  Looking at your samples, most should have order profiles for cell counting only, while analyses for other work areas (e.g. HbA1c or ESR) should not exceed 20-30% to keep up a smooth and fast workflow.

And if you need to archive your EDTA tubes and/or sort them for subsequent work areas, yet don't need sample pre-sorting or rack optimisation, Maximum Workload is the solution for you.

Technical specifications
Measurement principles WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Throughput
From 2 modules of XN-10/20 in
combination with SP-50 (H mode):


from 200 samples/h in whole blood (WB) mode,
up to 40 samples/h in body fluid (BF) mode per module,
up to 30 slides/h in standard mode per module,
up to 75 slides/h with the optional high-throughput licence per module
Aspiration volume
XN module:
SP-50 module:

88 μL in whole blood (WB) mode and body fluid (BF) mode
70 μL for smear preparation in auto mode,
38 μL for smear preparation in manual mode
Analysis parameters
Whole Blood

With RET (optional)
With PLT-F (optional)
With WPC (optional)
XN Stem Cells licence:
Body Fluids with XN-BF
(optional)

WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV,
P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG#
RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O
PLT-F, IPF, IPF#
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP#
HPC%, HPC#
WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF#
Sampler unit capacity 25 racks (250 samples) – Start Yard (ST-40) capacity
Integrated optional module DI-60 for digital image analysis
Tube sorter TS-10
Tosoh HLC-723 G11* – automated glycohaemoglobin analyser
Interrliner* – automated ESR reader
Staining protocols (SP-50) May Grünwald – Giemsa, Wright – Giemsa, Wright
Data storage capacities
(XN module)

Results: 100,000 samples
Patient information: 10,000 records
QC files: 99 files (300 plots per file)
Reagent replacement history: 5,000 records
X-bar control (L-J control): 300 plots x 94 files
X-barM control: 300 plots x 5 files

 

Contact us
You have a question and would like to get in touch with our experts? We look forward to receiving your enquiry.

Sysmex Europe SE

Bornbarch 1

22848 Norderstedt

Germany

+49 (40) 527 26 0

+49 (40) 527 26 100

Documents

Product documents

Safety data sheets

  • Filter by language
  • Bulgarian
  • Croatian
  • Czech
  • Danish
  • Dutch
  • English
  • Estonian
  • Finnish
  • French
  • German
  • Greek
  • Hungarian
  • Italian
  • Latvian
  • Lithuanian
  • Macedonian
  • Norwegian
  • Polish
  • Portuguese
  • Romanian
  • Russian
  • Serbian
  • Slovak
  • Slovenian
  • Spanish
  • Swedish
  • Turkish
  • Ukrainian

Regulatory documents

Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:

Go to My Sysmex

Explore more

XN-9100 Compact Integration

XN-9100 Compact Integration

Flexible and adaptable, ready to grow with you

Details
XN-9100 Sorting & Archiving

XN-9100 Sorting & Archiving

Powerful sample management for efficient processing

Details
XN-9100 Workload Balance

XN-9100 Workload Balance

Tube sorter becomes the sample manager

Details
Copyright © Sysmex Europe SE. All rights reserved.