XN-9100 Maximum Workload
Two worlds, one solution: High-speed screening of your bulk load – expert analysis for the pathological samples
- Combines two processing lines for fastest TAT – even at peak times
- Flexible configuration of XN analysis modules
- Discrete rack management
- Built-in auto reflex
The XN-9100 Maximum Workload best serves laboratories with a very high workload of EDTA blood sample tubes. You observe significant order entry peaks and need short turnaround times (TAT), while most of your samples are negative.
Ideally, you could do with two different processing lines: one for screening the bulk of the samples as fast as possible and another for analysing those with conspicuous results further. Looking at your samples, most should have order profiles for cell counting only, while analyses for other work areas (e.g. HbA1c or ESR) should not exceed 20-30% to keep up a smooth and fast workflow.
And if you need to archive your EDTA tubes and/or sort them for subsequent work areas, yet don't need sample pre-sorting or rack optimisation, Maximum Workload is the solution for you.
Measurement principles | WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry RBC/PLT: Hydrodynamically focussed impedance HGB: Cyanide-free SLS haemoglobin |
Throughput From 2 modules of XN-10/20 in combination with SP-50 (H mode): | from 200 samples/h in whole blood (WB) mode, up to 40 samples/h in body fluid (BF) mode per module, up to 30 slides/h in standard mode per module, up to 75 slides/h with the optional high-throughput licence per module |
Aspiration volume XN module: SP-50 module: | 88 μL in whole blood (WB) mode and body fluid (BF) mode 70 μL for smear preparation in auto mode, 38 μL for smear preparation in manual mode |
Analysis parameters Whole Blood With RET (optional) With PLT-F (optional) With WPC (optional) XN Stem Cells licence: Body Fluids with XN-BF (optional) | WBC, NRBC%, NRBC#, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, BASO%, BASO#, IG%, IG# RET%, RET#, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O PLT-F, IPF, IPF# Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP#, AS-LYMP%, AS-LYMP# HPC%, HPC# WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#, TC-BF# |
Sampler unit capacity | 25 racks (250 samples) – Start Yard (ST-40) capacity |
Integrated optional module | DI-60 for digital image analysis Tube sorter TS-10 Tosoh HLC-723 G11* – automated glycohaemoglobin analyser Interrliner* – automated ESR reader |
Staining protocols (SP-50) | May Grünwald – Giemsa, Wright – Giemsa, Wright |
Data storage capacities (XN module) | Results: 100,000 samples Patient information: 10,000 records QC files: 99 files (300 plots per file) Reagent replacement history: 5,000 records X-bar control (L-J control): 300 plots x 94 files X-barM control: 300 plots x 5 files |