RD-210
OSNA gene amplification detector
- Short TAT (~30 min up to 14 samples) – most of it as walk-away time
- High flexibility (intra-op and post-op usage; pan-cancer and multi-patient)
- Easy to operate, user-friendly integrated touchscreen
- Easy integration into a quality-controlled laboratory environment
OSNA – One Step Nucleic Acid Amplification – is an automated rapid molecular diagnostic test for the detection of lymph node (LN) metastases. It analyses the entire LN tissue using a reverse transcriptase loop-mediated isothermal amplification reaction (RT-LAMP*) to quantify tumour-specific cytokeratin 19 (CK19) mRNA expression in LNs.
The analyser to perform OSNA is a compact device, the RD-210. It is an easy to handle smooth process demanding few resources. Lymph node tissue from different patients or cancer types can be processed simultaneously, delivering results of up to 14 lymph nodes in a single run. If needed, it can provide quick results in an intraoperative setting.
* licensed under the agreement with Eiken Chemical CO., LTD
DETECTION CELL (cat #05437818) is an accessory for the OSNA automated molecular diagnostic test. It is composed of minute reaction chambers where nucleic acid amplification takes place.
PIPETTE TIP (cat #05437711) is an accessory to the OSNA automated molecular diagnostic test. Composed of volumetric filtered pipette tips for the automatic liquid handling of minute volumes of reagents and samples inside the RD-210.
RD Sample Vial (cat #BP675300) is an accessory to the OSNA automated molecular diagnostic test. Composed of 1.5 mL polypropylene vials for temporary sample storage.
Article number | CP437283 |
Measurement Principle | In the presence of CK19 RNA, Magnesium pyrophosphate precipitates during the amplification process, causing a white turbidity. The instrument measures the amount of light transmitted through the sample and calculates the copy number. |
Technology | RT-LAMP = Reverse transcriptase loop-mediated isothermal amplification; licensed under the agreement with Eiken Chemical CO., LTD |
Throughput | 2 sample analysis/run: within 16 min. 12 sec. |
Dimension | W600 mm x D780 mm x H610 mm |
Weight | ~ 90 kg |
Reagents | LYNOAMP CK19 E |
Disposables | DETECTION CELL PIPETTE TIP RD Sample Vial |
Parameter | CK19 mRNA copies/µl |
Sysmex Europe SE
Bornbarch 1
22848 Norderstedt
Germany
+49 (40) 527 26 0
+49 (40) 527 26 100
OSNA complete video training.
These trainings are intended for pathologists and everyone who operates the analyser.
Product documents
Safety data sheets
Regulatory documents
Regulatory documents, such as Instructions for Use, can be accessed with a valid My Sysmex login:
Go to My Sysmex